Warning List - Omron R88M-1M Series User Manual

Ac servomotors/servo drives
Hide thumbs Also See for R88M-1M Series:
Table of Contents

Advertisement

12 Troubleshooting

12-2-2 Warning List

General Warnings
Error No.
Main
Sub
(hex)
(hex)
A0
00
A1
00
A3
00
A4
00
A6
00
A7
01
02
04
05
06
AB
00
*1. For Warning Mask 1 Selection, when a bit is set to 1, the detection of the corresponding warning is disabled.
Precautions for Correct Use
You can clear these warnings by executing the error rest command. The command does clear
the warning even if the cause of the warning is not removed, but the same warning will occur
again.
12 - 8
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Warning name
Overload Warning
The load ratio of Servo Drive or motor
(4150-81 hex) exceeded the level set in
Overload - Warning Notification Level
(4150-01 hex).
Regeneration Overload
The Regeneration Load Ratio (4310-81
Warning
hex) exceeded 85% of the regeneration
overload ratio.
Fan Rotation Warning
The rotation speed of the fan is 80% or
less of the rating and the cooling perfor-
mance decreases.
Encoder
Encoder communications errors
Communications
occurred in series more frequently than
Warning
the specified value.
Motor Vibration
The motor vibration, which was higher
Warning
than or equal to the level set in the
Vibration Detection - Detection Level
(3B70-01 hex), was detected.
Capacitor Lifetime
The capacitor built into the Servo Drive
Warning
reached the service life of the manufac-
turer's guarantee.
Inrush Current
The inrush current prevention relay built
Prevention Relay
into the Servo Drive reached the service
Lifetime Warning
life of the manufacturer's guarantee.
Brake Interlock Output
The brake interlock output (BKIR) relay
Relay Lifetime Warning
built into the Servo Drive reached the
service life of the manufacturer's guar-
antee.
Lifetime Information
An error was detected in the saved life-
Corruption Warning
time information.
Encoder Lifetime
• The encoder lifetime is close to the
Warning
end.
• The encoder broke down.
Absolute Encoder
The multi-rotation counter of the
Counter Overflow
encoder exceeded the value set in
Warning
Encoder - Absolute Encoder Counter
Overflow Warning Level (4510-02
hex).
Warning condition
Warning Mask 1
*1
Selection
(4020-01 hex)
Warning Level Change 1
Selection (4020-05 hex)
corresponding bit
Bit 0
Bit 1
Bit 11
Bit 2
Bit 3
Bit 4
Bit 5
Bit 7
Bit 9
Bit 10
Bit 12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88m-1l seriesR88d-1sn ect seriesR88d-1sn01l-ectR88d-1sn02l-ectR88d-1sn04l-ectR88d-1sn01h-ect ... Show all

Table of Contents