Omron R88M-1M Series User Manual page 952

Ac servomotors/servo drives
Hide thumbs Also See for R88M-1M Series:
Table of Contents

Advertisement

Appendices
Event name
Brake Interlock Output Relay Lifetime Warning
The brake interlock output (BKIR) relay built into the Servo Drive reached the service life of the manufac-
Description
turer's guarantee.
EtherCAT Master Function Mod-
Source
ule
Error
Level
attributes
Effects
User program Continues.
EtherCAT NET RUN
Indicators
---
System
Variable
-defined
None
variables
Assumed cause
The number of operating times of
Cause and
the brake interlock output in the
correction
Servo Drive exceeded the ser-
vice life
Attached
None
information
Precautions/
AL status code: -, Error No.: A704 hex
Remarks
*1. You can change the level to minor fault by using Warning Level Change 1 Selection (4020-05 hex).
A - 166
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Source details
*1
Observation
Recovery
Operation
EtherCAT NET ERR
---
Data type
None
Correction
Send the Servo Drive for repair or
replace the Servo Drive with a new
one. It is necessary to replace the
component that reached the ser-
vice life.
Event code
081F0000 hex
Slave
Detection
timing
---
Log category
Not affected.
EtherCAT LINK/ACT
---
Name
None
Prevention
None
Continuously
System log

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88m-1l seriesR88d-1sn ect seriesR88d-1sn01l-ectR88d-1sn02l-ectR88d-1sn04l-ectR88d-1sn01h-ect ... Show all

Table of Contents