Error No.
Name
Main
Sub
(hex)
(hex)
35
00
FPGA WDT
Error
01
System Error
02
Self-diagno-
sis Error
36
00
Non-volatile
Memory Data
Error
37
00
Non-volatile
Memory
Hardware
Error
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Cause
An FPGA error was
False detection due to a
detected.
data read error that was
caused by excessive
noise
Hardware failure
A hardware error due to
False detection due to a
the self-diagnosis and a
data read error that was
fatal software error were
caused by excessive
detected.
noise
A fatal software error
was detected.
Hardware failure
An error was detected
False detection due to a
by the self-diagnosis of
data read error that was
the safety function.
caused by excessive
noise
Hardware failure
An error of data saved
Power interruption or
in the non-volatile mem-
noise occurred while
ory was detected.
parameters other than
the safety were saved
Power interruption or
noise occurred while the
motor identity informa-
tion was saved
Power interruption or
noise occurred while
safety parameters were
saved
An error occurred on the
False detection due to a
non-volatile memory.
data read error that was
caused by excessive
noise
Non-volatile memory
failure
12 Troubleshooting
Measures
If this event does not occur after
you cycled the power supply, use
the product continuously. It is sup-
posed that a temporary error
occurred due to a read error.
If this event occurs again, the hard-
ware is faulty. Replace the Servo
Drive.
If this event does not occur after
you cycled the power supply, use
the product continuously. It is sup-
posed that a temporary error
occurred due to a read error.
If this event occurs again, a fatal
error exists. Replace the Servo
Drive.
If this event does not occur after
you cycled the power supply, use
the product continuously. It is sup-
posed that a temporary error
occurred due to a read error.
If this event occurs again, replace
the Servo Drive.
Save data after setting the parame-
ter again, and cycle the power sup-
ply.
Execute Motor Setup, and cycle the
power supply.
Clear the FSoE slave address, exe-
cute FSoE Enable Reset, and cycle
the power supply.
After you cycled the power supply, if
this error occurs continuously
although the error is reset, the
non-volatile memory is faulty.
Replace the Servo Drive.
12
12 - 25