Method For Broken Ring Maintenance And Inspection - Omron R88M-1M Series User Manual

Ac servomotors/servo drives
Hide thumbs Also See for R88M-1M Series:
Table of Contents

Advertisement

13-4 Method for Broken Ring Maintenance
and Inspection
This section takes the following example of a configuration in which the ring is broken between Servo
Drive A and B, and describes how to perform inspection and how to replace the Servo Drive.
1
Identify where the ring is broken.
• With a tool such as support software, find the node address of the Servo Drive breaking the
ring. For the NJ/NX-series Controller, check the _EC_RingBreakNodeAdr system-defined
variable that will provide you with the node address of Servo Drive A. Check that the L/A OUT
indicator of Servo Drive A and the L/A IN indicator of Servo Drive B are OFF.
2
Reconnect the EtherCAT communications cable between Servo Drive A and B.
• Stop operation and turn OFF the power supply to the EtherCAT master and to the slaves.
• After the charge lamps of Servo Drive A and B turn OFF, reconnect the EtherCAT communi-
cations cable, and then turn ON the control power supply to Servo Drive A and B.
• If the L/A OUT indicator of Servo Drive A and the L/A IN indicator of Servo Drive B are ON,
the ring disconnection status has been fixed.
• If the L/A IN and L/A OUT indicators are OFF, the ring disconnection status has not been fixed
yet. Move on to the next step.
3
Replace the relevant cable with a new EtherCAT communications cable.
• Replace the EtherCAT communications cable between Servo Drive A and B with a new cable.
To avoid incorrect wiring, do not remove any other cable.
• If the L/A OUT indicator of Servo Drive A and the L/A IN indicator of Servo Drive B are ON or
blink, the ring disconnection status has been fixed.
• If the L/A IN and L/A OUT indicators are OFF, Servo Drive A or B is faulty. Move on to the next
step.
4
Identify the faulty Servo Drive.
• As in the following figure, connect one EtherCAT communications cable to the ECAT IN and
ECAT OUT connectors on Servo Drive A. If the L/A IN and L/A OUT indicators remain OFF,
Servo Drive A is faulty.
• In the same way, connect one EtherCAT communications cable to the ECAT IN and ECAT
OUT connectors on Servo Drive B. If the L/A IN and L/A OUT indicators remain OFF, Servo
Drive B is faulty.
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
L1
L2
Servo Drive A
L/A L/A
RUN
ERR
IN OUT
FS
13 Maintenance and Inspection
L3
Servo Drive B
Servo Drive C
L/A L/A
RUN
ERR
IN OUT
FS
L4
L/A L/A
RUN
ERR
IN OUT
FS
13
L5
13 - 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88m-1l seriesR88d-1sn ect seriesR88d-1sn01l-ectR88d-1sn02l-ectR88d-1sn04l-ectR88d-1sn01h-ect ... Show all

Table of Contents