6-200 Section 060-INDP-610 Maintenance Procedures Guide
Procedure 6-46
Four-Channel Communication PCA replacement (NT6M85AA)
Step
Description
165
Seat the rear panel in its fully seated position and reinstall the slotted pan head screws
previously removed.
166
Verify that the MMI functions are operating properly.
The procedure is complete.
Table 6-24
Four-Channel Communications PCA (A17) options - part number: NT6M85AA
Device type
(number)
Jumper
(J6)
Jumper
(J7)
Jumper
(J8)
Jumper
(J9)
Jumper
(J10)
Strap
DIP Switch
Rotary Switch
297-6201-502 Standard 01.02 September 2000
Position/setting
2-3
1-2
2-3
1-2
2-3
1-2
2-3
1-2
2-3
1-2
None Used
None Used
None Used
(Sheet 3 of 3)
Function
ADU Operation
No ADU operation
(EIA on chan 1 & 2)
ADU Operation
No ADU operation
(EIA on chan 1 & 2)
ADU Operation
No ADU operation
(EIA on chan 1 & 2)
ADU Operation
No ADU operation
(EIA on chan 1 & 2)
ADU Operation
No ADU operation
(EIA on chan 1 & 2)
Setting
Factory
On-site
1-2
Must be
same as
factory
setting.
1-2
Must be
same as
factory
setting.
1-2
Must be
same as
factory
setting.
1-2
Must be
same as
factory
setting.
1-2
Must be
same as
factory
setting.