4-94 Section 060-INDP-410 Command and Message Guide
Table 4-22
00 PIO TEST FAILED message
1 0
Other Alarm Indications
1 1
System Recovery Action
1 2
Craftsperson Activity:
Table 4-23
ACTIVE PROC ALARM - NO SWITCH message
1 3
ACTIVE PROC ALARM - NO
SWITCH
Display: Log message
1 4
Alarm Level:
No processor switch possible
1 5
Customer-Selected Alarm Level
1 6
Other Alarm Indications
297-6201-502 Standard 01.02 September 2000
Default:
Status Panel:MajorAudible:Major
Customer-Selected
Status Panel:Audible:
None
If the standby processor is off, this message is normal.
If the standby processor is on, refer to the Boot
Recovery Procedure in the Maintenance Procedures
Guide section.
Cause: active processor is in alarm and therefore
should have switched prior to this printout. The switch
did not take place for one of the following reasons:
a. standby processor is not powered up
b. standby processor is in a higher alarm condition than
the active processor.
Reason Code = 40
Corresponds to ERRMAP entry:
STNBY COMM DOWN
System Default:
Type:MajorLevel:0
Type:Level:
Default:
Status Panel:MajorAudible:Major
Customer-Selected
Status Panel:Audible: