Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 270

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

4-110 Section 060-INDP-410 Command and Message Guide
Table 4-42
Bx TEC TIME OUT message
1 2 7
(log message)
B0 TEC TIME OUT
(log message)
B2 TEC TIME OUT
Display: Log message
1 2 8
Alarm Level:
Processor switch: if the message is
from the active TEC/DSI PCA
during normal operation = Major
Alarm, Level 1.
No switch: if the message is from
the standby TEC/DSI PCA during
normal operation = Minor Alarm,
Level 0.
None: if at power-up.
1 2 9
Customer-Selected Alarm Level
1 3 0
Other Alarm Indications
1 3 1
System Recovery Action
1 3 2
Craftsperson Activity:
297-6201-502 Standard 01.02 September 2000
Where: x = TEC/DSI Port ID
= 0 = TEC/DSI PCA in slot 13.
= 2 = TEC/DSI PCA in slot 12.
Cause: output when a request for the transfer of a data
block (read or write) is ignored. Message is from the
TEC/DSI PCA. May be caused by the Switching
System attempting to read data that the BMC does not
presently have available, usually during a test
sequence (i.e., attempt to read header data without a
rewind command first).
Reason Code = 25
Corresponds to ERRMAP entry:
TEC STNBY FAIL Minor Alarm, Level 0 (or)
TEC PRIME FAIL Major Alarm, Level 1
System Default:
Type:See Alarm LevelLevel:N/A
Type:Level:
Default:
Status Panel: See Alarm Level Audible:
Customer-Selected
Status Panel:
Audible:
a. Processor switch if the message is from the active
TEC/DSI PCA port.
b. No processor switch if the message is from the
standby TEC/DSI PCA port.
Refer to the TEC/DSI PCA Diagnostic Procedure in the
Maintenance Procedures Guide section.