Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 697

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

Table 8-2
Connector to Quad SIO PCA Cross-Reference
BMC connectors on side
of A chassis
Connecto
Function
r
* factory setting for this switch or jumper.
Note 7: This PCA supports polling on digital data lines or on analog network. For digital data lines
check that:
a. the P/A Comm PCA at A16 is part number NT6M84BA
b. the Four Channel COMM PCA at A17 is release 03 or later
c. the HOC supports the digital data line feature.
Note 8: The internal transmit timing source is generated on the Quad SIO PCA. The external
transmit timing source is brought in from a source outside the BMC, usually associated with a
modem generated timing source from a digital data line.
Note 9: Factory settings shown are for external timing.
Note 10: Verify that the settings on the jumpers J2-J13 on the Quad SIO PCA are in agreement
with the settings on the P/A Comm PCA (A16) when working with digital data lines.
Note 11: For DIP Switch S6, do not set the switches (S6-1, S6-2, S6-3, and S6-4) to the ON
position.
Note 12: For Switch S1, the switch setting must remain at A.
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-711 DMS-100 Switch Specific Data 8-17
Quad SIO PCA settings
Rotary Switch
Option Jumpers Definitions
# Settings
Sheet 2 of 2