4-134 Section 060-INDP-410 Command and Message Guide
Table 4-68
CP SCC Channel x test: DMA Busy message
2 8 3
CP SCC Channel x test: DMA Busy
Display: Maintenance terminal
2 8 4
Alarm Level:
N/A
2 8 5
Customer-Selected Alarm Level
2 8 6
Other Alarm Indications
2 8 7
System Recovery Action
2 8 8
Craftsperson Activity:
297-6201-502 Standard 01.02 September 2000
Where: x = channel identifier (A or B)
Cause: response to the CP TEST ACT or CP TEST
STDBY command; this message should never appear.
If the CP TEST ACT or CP TEST STDBY command is
entered during a polling session, the message, CP
DGN - Testing not performed due to a polling, should
appear. If the message, CP SCC Channel x test: DMA
Busy, does appear, this implies there is a hardware or
internal software problem on the 56K Interface PCA.
Reason Code = N/A
Corresponds to ERRMAP entry: N/A
System Default:
Type:N/ALevel:N/A
Type:Level:
Default:
Status Panel: Audible:
Customer-Selected
Status Panel:Audible:
None
Refer to the 56K Interface PCA Diagnostic Procedure in
the Maintenance Procedures Guide section.