4-264 Section 060-INDP-410 Command and Message Guide
Table 7-208
xxxIDX FILE FAILURE message
2 2 9
AMAIDX FILE FAILURE
LOGIDX FILE FAILURE
Display: Maintenance terminal
2 3 0
Alarm Level:
Processor switch occurs
2 3 1
Customer-Selected Alarm Level
2 3 2
Other Alarm Indications
2 3 3
System Recovery Action
2 3 4
Craftsperson Activity:
297-6201-502 Standard 01.02 September 2000
Cause: output when an attempt to update a record
index file fails.
Reason Code = 03
Corresponds to ERRMAP entry: DSK INDEX ERROR
System Default:
Type:MinorLevel:0
Type:Level:
Default:
Status Panel:MinorAudible:Minor
Customer-Selected
Status Panel:Audible:
Processor switch
Refer to the Index Corruption Recovery Procedure in
the Maintenance Procedures Guide section.