Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 325

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

Table 7-96
DISK: BUS CONTROLLER INTERRUPT WHILE IDLE message
1 3 3
(log message)
DISK: BUS CONTROLLER
INTERRUPT WHILE IDLE
AUXILIARY STATUS: xx,
INTERRUPT STATUS yy
Display: Log message
1 3 4
Alarm Level:
Possible change in disk mode
1 3 5
Customer-Selected Alarm Level
1 3 6
Other Alarm Indications
1 3 7
System Recovery Action
1 3 8
Craftsperson Activity:
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-410 Command and Message Guide 4-165
Where:
xx = contents of the bus controller auxiliary status
register (in Hex).
yy = contents of the bus interrupt status register (in
Hex).
Cause: output when the SCSI Interface or the SCSI bus
controller generates an unexpected interrupt.
Reason Code = 27
Corresponds to ERRMAP entry: DISK ER MESSAGE
System Default:
Type:MinorLevel:0
Type:Level:
Default:
Status Panel:MinorAudible:Minor
Customer-Selected
Status Panel:Audible:
None
Refer to the description of the TEST command in this
document. If the problem continues, refer to the Disk
Drive Diagnostics Procedure in the Maintenance
Procedures Guide section.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dms-100 series

Table of Contents