6-32 Section 060-INDP-610 Maintenance Procedures Guide
Table 6-4
Data Definitions
Position
00330000AA
AA
5 characters after AA
C
011CBBBBBB
BBBBBB
Boot Recovery Procedure
This procedure assumes the user has been referred here by a failure message.
There are a number of different alarms that could refer the user to this
procedure. This procedure should only be started when user has verified the
alarm is on the standby processor using the ERRMAP ALARMS command.
297-6201-502 Standard 01.02 September 2000
Definition
4 bytes before AA are Record Descriptor Word (RDW) for following call
record
Start of new call record
Structure code for call, refer to the Commands and Messages Guide
section for breakdown of fields and definitions
Field separator within call record
Last two bytes of block (includes C) is CRC for parity
As at end of block are fill characters from Switching System