Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 464

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

6-26 Section 060-INDP-610 Maintenance Procedures Guide
Procedure 6-8
56K Interface PCA Diagnostic
Step
Description
84
Enter the following commands to verify that the BOOTCP file contains the software load
and version number of the program file on the disk.
>CP BOOT LIST (cr)
System response: filename vers
where:
filename- name of the CP boot file.
vers- version number.
>LSTDIR FILE BOOTCP 1 255 (cr)
System response: xx BOOTCP xx vers xx xx xx xx xx xx xx xx xx
The value of xx is not important to this procedure.
There will be one response line for each file found on the disk. It is normal for only one
version of the BOOTCP file to be on the disk. Compare the list of files output from the
LSTDIR command to verify that a file matching the result of the CP BOOT LIST is on the
disk.
If the BOOTCP file was found on the disk, go to step 4. If the BOOTCP file was not found,
contact your next level of support.
85
Enter the following command to attempt to reboot the suspect 56K Interface PCA:
>CP BOOT ACT (cr)
or
>CP BOOT STDBY (cr)
A CP ACTIVE message is displayed once the program successfully loads. The BMC
attempts to load the software program into the 56K Interface PCA up to three times.
If booting the 56K Interface PCA fails, replace the 56K Interface PCA using the procedure
in the Hardware Replacement subsection. When the PCA replacement is completed,
repeat this procedure from the beginning.
If the 56K Interface PCA has already been replaced and the CP boot still fails, contact
your next level of support. If the CP program loads, continue with step 5.
297-6201-502 Standard 01.02 September 2000
Sheet 2 of 4