Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 267

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

Table 4-39
Bx TEC COMM FAIL message
1 0 9
(log message)
B0 TEC COMM FAIL
(log message)
B2 TEC COMM FAIL
Display: Log message
1 1 0
Alarm Level:
Processor switch: if the message is
from the active TEC/DSI PCA
during normal operation = Major
Alarm, Level 1.
No switch: if the message is from
the standby TEC/DSI PCA during
normal operation = Minor Alarm,
Level 0.
None: if at power-up.
1 1 1
Customer-Selected Alarm Level
1 1 2
Other Alarm Indications
1 1 3
System Recovery Action
1 1 4
Craftsperson Activity:
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-410 Command and Message Guide 4-107
Where: x = TEC/DSI Port ID
= 0 = TEC/DSI PCA in slot 13.
= 2 = TEC/DSI PCA in slot 12.
Cause: output when the processor cannot
communicate with the TEC/DSI PCA. Tested
automatically every 20 minutes.
Reason Code = 24
Corresponds to ERRMAP entry:
TEC STNBY FAIL Minor Alarm, Level 0 (or)
TEC PRIME FAIL Major Alarm, Level 1
System Default:
Type:See Alarm LevelLevel:N/A
Type:Level:
Default:
Status Panel: See Alarm Level Audible:
Customer-Selected
Status Panel:
a. Processor switch if the message is from the active
TEC/DSI PCA port.
b. No processor switch if the message is from the
standby TEC/DSI PCA port.
Refer to the TEC/DSI PCA Diagnostic Procedure in the
Maintenance Procedures Guide section.
Audible: