Procedure 6-25
Polling Diagnostic
Step
Description
Enter the following command to write this site dependent data to disk:
>SITDAT WRITE (cr)
System response: SITDAT FILE DISK JOB COMPLETE
On-Site Procedures for Disk Drives
This section describes the procedures that are performed on-site for the BMC
disk drive units.
Download and Boot Software with Software Running
The main software programs for the BMC are written on disk before the
systems are shipped from Nortel. Periodic updates and patches to the
software programs are issued and must be loaded onto disk as part of on-site
activities. The following procedure provides the method for downloading and
booting new software with the old software still running.
Procedure 6-26
Download and Boot Software with Software Running
Step
Description
65
Interface a modem to a phone line and the BMC's downloading port at J2.
66
Adjust the baud rate, if necessary (1200-9600 per modem selection).
67
Check that space is available on disk and in the disk directory for the downloaded
program. Enter (at the terminal):
>LSTDIR ALL (cr)
Note: Directory maximum is 383 files.
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-610 Maintenance Procedures Guide 6-79
(Sheet 7 of 7)
(Sheet 1 of 7)