6-48 Section 060-INDP-610 Maintenance Procedures Guide
Procedure 6-13
Disk Drive Full
Step
Description
142
Enter the following command to verify all data is polled:
>IDXMAINT SUMMARY AMA (cr)
If response indicates 00000000 PRIMARY on the first line, proceed to step 8. If response
does not indicate 00000000 PRIMARY, have data center poll again.
143
Enter the following command to verify disk usage to determine whether it is at an
acceptable level.
>DISK USAGE (cr)
Example response:
00108/30517 ALLOCATION UNITS USED
Divide the number in front of the slash by the number after the slash to derive usage
percentage. If usage is still above 70%, proceed to step 10. If usage is within the 70%
range, proceed to step 9.
144
When polling is complete, enter the following command to make the disk mode redundant
again.
>DISK MODE xP (cr)
where: x - A or B (if disk mode was changed to BO in step 4, enter B for x).
Length of time to perform this step varies depending on the disk usage. When BMC
responds with DISK MODE:AP/BP, this procedure is complete.
297-6201-502 Standard 01.02 September 2000
Sheet 3 of 5