3-12 Section 060-INDP-310 System Administration Guide
Alarm Handling Activity
The ERRMAP command is used to list or assign all the alarm type, status and
level assignments. A complete list of all ERRMAP entries is provided in the
example ERRMAP response below.
CURRENT ALARM ASSIGNMENTS ARE:
DEV/EVT.NAMEALARMLEVEL
01NO BLK LAST PERMINOR 0
02TEC STDBY FAILMINOR 0
03TEC PRIME FAILMAJOR 1
04D_RAM ERRORMAJOR 1
05SIO-1 FAILUREMAJOR 1
06ERROR CTL CONFLMAJOR 1
07ERROR CTL INCONMAJOR 0
08DMA COMM FAILMAJOR 2
09PROC STAT ALARMMAJOR 2
10PROG CKSUM ALMMAJOR 3
11TEC DATA OVERFLOCRITICAL 0
12NO CLK TIME SETMINOR 0
13PLANNED SWITCHPSWITCH 0
14ONLY NON-REDUNDMINOR 0
15STNBY COMM DOWNMAJOR 0
16PROM CKSUM FAILMAJOR 3
17DSK 70% PRIMARYMINOR 0
18DSK 90% PRIMARYMAJOR 0
19OFFLIN DSK FULLMAJOR 0
20DSK STORE LIMITCRITICAL 0
21DISK WRITE FAILMAJOR 2
22DSK INDEX ERRORMINOR 0
23NO INDEX FILEMAJOR 0
24DIRECTORY FULLCRITICAL 0
25SITE FILE ERRORMINOR 0
26STAT FILE ERRORMINOR 0
27EXCESS INV BLKSMINOR 0
28CP NOT AVAIL.MAJOR 1
29CP FAULTMAJOR 1
30DSK ERROR ALARMCRITICAL 0
31DISK MODE ALARMMAJOR 0
32DSK CARD HW ERRMAJOR 2
33DISK ER MESSAGEMINOR 0
* INDICATES CURRENTLY ACTIVE ALARM(S)
TO CHANGE ERRMAP TABLE, ENTER:
ERRMAP DEV/EVT# ALARMTYPE LEVEL
During operation, errors may be encountered. Since some errors are more
serious than others, the BMC provides a means of controlling the operation
when errors are encountered. In more serious cases, the BMC can switch
active processors, change operating mode (PRIME to ONLY) and change
297-6201-502 Standard 01.02 September 2000
Note: Follow this command with the SITDAT WRITE and LINIT
command to make the change permanent and transfer the data to the CP.