4-8 Section 060-INDP-410 Command and Message Guide
Table 4-4
ERRMAP device/event names
Event
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
To assign or change an alarm event, alarm type, or alarm level for the active
processor only, enter the following command:
>ERRMAP event alarm level (cr)
The system responds by displaying an ERRMAP printout with the changed
data. Be sure to issue the SITDAT WRITE and LINIT commands to save new
data to disk and send the new values to the CP.
297-6201-502 Standard 01.02 September 2000
Event name
OFFLIN DSK FULL
DSK STORE LIMIT
DISK WRITE FAIL
DSK INDEX ERROR
NO INDEX FILE
DIRECTORY FULL
SITE FILE ERROR
STAT FILE ERROR
EXCESS INV BLKS
CP NOT AVAIL.
CP FAULT
DSK ERROR ALARM
DISK MODE ALARM
DSK CARD HW ERR
DISK ER MESSAGE
Sheet 2 of 2
Alarm
Level
Major
0
Critical
0
Major
2
Minor
0
Major
0
Critical
0
Minor
0
Minor
0
Minor
0
Major
1
Major
1
Critical
0
Major
0
Major
2
Minor
0