Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 407

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

Table 7-190
SCSI: INTERRUPT WHILE IDLE message
1 2 3
Customer-Selected Alarm Level
1 2 4
Other Alarm Indications
1 2 5
System Recovery Action
1 2 6
Craftsperson Activity:
Table 7-191
SDI COM FAIL message
1 2 7
(log message)
SDI COM FAIL
Display: Log message
1 2 8
Alarm Level:
N/A
1 2 9
Customer-Selected Alarm Level
1 3 0
Other Alarm Indications
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-410 Command and Message Guide 4-247
Type:Level:
Default:
Status Panel:MinorAudible:Minor
Customer-Selected
Status Panel:Audible:
None.
Verify the disk drive strapping. If correct, refer to the
Disk Drive Diagnostic Procedure in the Maintenance
Procedures Guide section.
Cause: occurs when the DMS-10 password is set
(using the DMSP command), but the login fails to due a
communications problem or incorrect password.
Reason Code = N/A
Corresponds to ERRMAP entry: N/A
System Default:
Type:N/ALevel:N/A
Type:Level:
Default:
Status Panel:Audible:
Customer-Selected
Status Panel:Audible:

Hide quick links: