Procedure 6-13
Disk Drive Full
Step
Description
138
Enter the following command to verify that all data is polled:
>IDXMAINT SUMMARY AMA (cr)
Response should indicate 00000000 PRIMARY on the first line. If response does not
indicate 00000000 PRIMARY, have data center poll again. If AMA continues to be written
while polling is taking place, reschedule activity for another time when traffic is slower or
reroute traffic to another device.
139
Enter the following command to change disk mode to access AMA from disk B that needs
to be polled by the HOC:
>DISK MODE BO (cr)
System response: DISK MODE BO
140
Enter the following commands to verify that AMAIDX is correct and that data needed by
HOC is available.
>IDXMAINT CHECK AMA (cr)
System response: GOOD AMAIDX FILE
>IDXMAINT DIR CLOSED AMA 255 (cr)
System responds with the versions contained in the AMAIDX and the starting sequence
number of each version. If AMAIDX is not good, use the procedure in the Index Corruption
Recovery Procedure subsection to create a new AMAIDX. If sequence numbers needed
by data center are not within the boundaries of the starting sequence numbers listed
above, proceed to step 10.
141
Have data center poll data.
Note: Incoming AMA data will be written during the time data center is polling.
CAUTION
Do not proceed until data center has completed polling.
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-610 Maintenance Procedures Guide 6-47
Sheet 2 of 5