Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 244

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

4-84 Section 060-INDP-410 Command and Message Guide
To delete the last file name from the list contained in the boot file, enter the
following at the maintenance terminal:
>DOS LD (cr)
To list the contents of a boot file, enter the following at the maintenance
terminal:
>DOS LL (cr)
To read 16 bytes of firmware or software memory, starting at a specified
address, enter the following at the maintenance terminal:
>DOS M xxxxx (cr)
where:
xxxxx - starting address in HEX (0000-3FFFF).
To write bytes of data to program memory (firmware cannot be changed),
starting at a specified address, enter the following at the maintenance
terminal:
>DOS M xxxx aa bb... (cr)
where:
xxxx - starting address
aa, bb - data to be written.
To read data from memory, enter the following at the maintenance terminal:
>DOS M xxxx /. (cr)
where:
xxxx - starting address.
To communicate with the standby processor, enter the following at the
maintenance terminal:
>DOS S cmd (cr)
where:
cmd - any software or firmware command.
297-6201-502 Standard 01.02 September 2000
Note 25: Disk commands cannot be directed to the standby processor.