Table 4-71
CP TASK ERR message
3 0 1
CP TASK ERR
Display: Log message
3 0 2
Alarm Level:
Major
3 0 3
Customer-Selected Alarm Level
3 0 4
Other Alarm Indications
3 0 5
System Recovery Action
3 0 6
Craftsperson Activity:
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-410 Command and Message Guide 4-137
Cause: an illogical condition was detected by the 56K
Interface PCA system software.
Reason Code = N/A
Corresponds to ERRMAP entry: CP FAULT
System Default:
Type:MajorLevel:1
Type:Level:
Default:
Status Panel: MajorAudible:Major
Customer-Selected
Status Panel:Audible:
System attempts a 56K Interface restart. If the 56K
Interface cannot successfully complete a restart, the
alarm is upgraded to CP NOT AVAILABLE.
Refer to the 56K Interface PCA Diagnostic Procedure in
the Maintenance Procedures Guide section. If problems
continue, refer to the 56K Interface PCA Replacement
Procedure in the Maintenance Procedures Guide
section.
CP NOT AVAIL.