Table 4-43
Bx TEC WARM START message
1 3 3
(log message)
B0 TEC WARM START
(log message)
B2 TEC WARM START
Display: Log message
1 3 4
Alarm Level:
Processor switch: if the message is
from the active TEC/DSI PCA
during normal operation = Major
Alarm, Level 1.
No switch: if the message is from
the standby TEC/DSI PCA during
normal operation = Minor Alarm,
Level 0.
None: if at power-up.
1 3 5
Customer-Selected Alarm Level
1 3 6
Other Alarm Indications
1 3 7
System Recovery Action
1 3 8
Craftsperson Activity:
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-410 Command and Message Guide 4-111
Where: x = TEC/DSI Port ID
= 0 = TEC/DSI PCA in slot 13.
= 2 = TEC/DSI PCA in slot 12.
Cause: output at restart with RAM intact (program not
returning watchdog command). Message is from the
TEC/DSI PCA.
Reason Code = 25
Corresponds to ERRMAP entry:
TEC STNBY FAIL Minor Alarm, Level 0 (or)
TEC PRIME FAIL Major Alarm, Level 1
System Default:
Type:See Alarm LevelLevel:N/A
Type:Level:
Default:
Status Panel: See Alarm Level Audible:
Customer-Selected
Status Panel:
a. Processor switch if the message is from the active
TEC/DSI PCA port.
b. No processor switch if the message is from the
standby TEC/DSI PCA port.
c.
Normal after power-up.
Refer to the TEC/DSI PCA Diagnostic Procedure in the
Maintenance Procedures Guide section.
Audible: