Example of Displayed Block
96-05-21 13:04:08 TUE PROC-B
OOOXXX AMA SEQ #61524
00 00 FO 54 F5 05 1A 00 05 20 11 42 00 00
00330000AA00020COOIC70120CO0000CO000000COCOCOCOOOC503C6641210CIC
00503C7724380C1140598CO00000119COCO11C00300000AAOOOOICO06C70120C
.
.
...............................0002266COCO11CBBBBBBBBBBBBBBBBBBB
Table 6-3
Header Definitions
Data
00 00 FO 54
1-4
F5 05
5-6
1A
7
00
8
05
9
20
10
11
11
42
12
00 00
13-14
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-610 Maintenance Procedures Guide 6-31
.
.
Byte
Definition
Block Sequence Number (hex)
Block size in bytes (hex)
Number of AMA calls in the block (hex)
Flag byte
Month block was received by BMC
Day block was received by BMC
Hour block was received by BMC
Minute block was received by BMC
Unused bytes
.
.