Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 401

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

Table 7-183
PROG CHKSUM ALM VAL = nn message
7 9
(log message)
PROG CHKSUM ALM VAL = nn
Display: Log message
8 0
Alarm Level:
Processor switch
8 1
Customer-Selected Alarm Level
8 2
Other Alarm Indications
8 3
System Recovery Action
8 4
Craftsperson Activity:
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-410 Command and Message Guide 4-241
Where: nn = difference from 0 of the calculated
checksum
Cause: output when a program memory verification has
failed for a downloaded program.
Reason Code = 10
Corresponds to ERRMAP entry: PROG CKSUM ALM
System Default:
Type:MajorLevel:3
Type:Level:
Default:
Status Panel:MajorAudible:Major
Customer-Selected
Status Panel:Audible:
A processor switch occurs and an attempt is made to
reload from the standby processor.
Refer to the Boot Recovery Procedure in the
Maintenance Procedures Guide section.