Table 7-152
KERNEL SERVICE ERROR - xxx message
2 3 1
Customer-Selected Alarm Level
2 3 2
Other Alarm Indications
2 3 3
System Recovery Action
2 3 4
Craftsperson Activity:
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-410 Command and Message Guide 4-215
Type:Level:
Default:
Status Panel:N/AAudible:N/A
Customer-Selected
Status Panel:Audible:
Polling may be affected by the error condition that
caused the message to print.
a. If the message persists, reboot the CP using the
following command:
>CP BOOT ACT (cr)
If the error message does not repeat, the procedure is
complete. If the message does repeat, proceed to step
b.
b. Replace the SCSI Interface PCA in the Standby
Processor. Refer to the associated procedure in the
Maintenance Procedures Guide section.
If after PCA replacement the error message repeats,
return the PCA to its original position and proceed to
step c.
c.
Call your next level of support.