Procedure 6-26
Download and Boot Software with Software Running
Step
Description
90
Display all site specific data and match and compare to that data extracted in step 8.
Verify that all editing has been completed correctly. If there are discrepancies, go back to
step 25.
91
Save the edited site specific data parameters on disk. Enter (at the terminal):
>SITDAT WRITE (cr)
The new SITDAT is read by the Processor during a Processor switch or power up, using
the newly edited site data. Successful SITDAT save on disk is indicated by the expected
message:
SITDAT FILE DISK JOB COMPELTE
92
Newly Active Processor reads SITDAT file from disk as saved in step 27, eliminating a
repeat of the manual editing of the site specific data. Enter (at the terminal):
>SWACT (cr)
A successful processor is indicated by the expected message:
MP SWITCH
This completes the installation.
Emergency Download and Boot Software with Software Not Running
At power-up, the software programs are automatically downloaded from disk
to RAM. The inability of the system to retrieve the program(s) from one or
both disk(s) requires use of manual downloading to restart the system. The