4-112 Section 060-INDP-410 Command and Message Guide
Table 4-44
CALL RECORD BLOCK FROM TEC INCORRECT message
1 3 9
(log message)
CALL RECORD BLOCK FROM TEC
INCORRECT
Display: Log message
1 4 0
Alarm Level:
No processor switch
1 4 1
Customer-Selected Alarm Level
1 4 2
Other Alarm Indications
1 4 3
System Recovery Action
1 4 4
Craftsperson Activity:
297-6201-502 Standard 01.02 September 2000
Cause: output for one of the following reasons:
a. data block received from the Switching System is not
a valid LSSGR billing data block.
b. communications between the BMC MP and a TEC/
DSI PCA is faulty.
c.
communication between Switching System and a
TEC/DSI PCA is faulty.
Reason Code = N/A
Corresponds to ERRMAP entry: EXEC INVALID REC
System Default:
Type:MajorLevel:0
Type:Level:
Default:
Status Panel:MajorAudible:Major
Customer-Selected
Status Panel:Audible:
Alarm is set.
Refer to the TEC/DSI PCA Diagnostic Procedure in the
Maintenance Procedure Guide section.