Procedure 6-24
No Block Last Hour Diagnostic
Step
Description
42
Enter the following command to examine the alarms on the error map and the BMC
current time. If there are any other alarms listed in the error map, troubleshoot those
alarms prior to the NO BLOCK LAST PER alarm.
>ERRMAP ALARMS (cr)
System responds with a list of alarms on the active and standby processors.
>CLK (cr)
System responds with the current time and date and the identity of the active processor.
>AMAHRS (cr)
System response:
BLOCK CHECK START ss ENDING ee INTERVAL ii
where:
ss- start time
ee- end time
ii- interval.
If the BMC time is not correct, go to step 2. If the BMC time is correct, go to step 3.
43
Enter the following command to set the BMC clock to the correct time:
>SETCLK yy mm dd hh mm ss ddd (cr)
where:
yy- Year
mm- Month
dd- Day
hh- Hour
mm- Minute
ss- Second
ddd- MON, TUE, WED, THU, FRI, SAT, or SUN.
System responds with the time and date along with the active processor identity.
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-610 Maintenance Procedures Guide 6-69
(Sheet 1 of 4)