4-232 Section 060-INDP-410 Command and Message Guide
Table 7-172
NO SEL message
1 3
(log message)
NO SEL
(No Select)
Display: Log message
1 4
Alarm Level:
if active unit = processor switch
= Major alarm; Level 1
if standby unit = no processor
switch = Minor alarm; Level 0
1 5
Customer-Selected Alarm Level
1 6
Other Alarm Indications
1 7
System Recovery Action
1 8
Craftsperson Activity:
297-6201-502 Standard 01.02 September 2000
Cause: output when a tape command line status is
TRUE, but is not accompanied by Unit Select Status
(USEL).
This output should not appear during normal operation;
used by Nortel for test and verification purposes only.
Ignore this message if it appears when changing TEC/
DSI PCAs or removing TEC/DSI cables.
Reason Code = N/A
Corresponds to ERRMAP entry: TEC PRIME FAIL or
TEC STNBY FAIL
System Default:
Type:See Alarm LevelLevel:N/A
Type:Level:
Default:
Status Panel:See Alarm Level Audible:
Customer-Selected
Status Panel:
Audible:
a. If the message is from the active unit (Major Alarm,
Level 1), a processor switch occurs.
b. If the message is from the standby unit (Minor
Alarm, Level 0), no processor switch occurs.
Verify cable placement and status of the MTU ports in
the Switching System. In addition, refer to the TEC/DSI
PCA Diagnostic Procedure in the Maintenance
Procedures Guide section.