Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 208

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

4-48 Section 060-INDP-410 Command and Message Guide
The system displays the requested data in the following format:
xxxx yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy
xxxx yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy yy
where:
xxxx - data address
yy
To examine a specified number of lines of program space information at a
specified address, enter the following command:
>SYSUTIL EXAMINE P addr nlines (cr)
The system displays the program space data in the same format as the data
space information is displayed, as shown above.
SYSUTIL IOREAD
SYSUTIL IOREAD reads data from a specified I/O port.
Example of command usage
Use the following command to read data from a specified I/O port:
>SYSUTIL IOREAD port (cr)
where:
port- specifies the port. Range: 0-FF.
The system displays the requested data from the specified I/O port as follows:
xx
where:
297-6201-502 Standard 01.02 September 2000
CAUTION 2
Improper use of this command may result in an attempt to
write data to a non-existent memory location, or, cause
erroneous data to be written to a memory location that is
already in use by other data. Do not use this command
without first contacting technical assistance personnel to
determine that it is proper to do so.
- data bytes (hex).