6-192 Section 060-INDP-610 Maintenance Procedures Guide
Procedure 6-44
Bus Terminator PCA replacement (NT6M68AA) - version numbers G12 or earlier (e.g., D09 or
E12)
Step
Description
122
Enter the following command at the maintenance terminal to Switch Processors to
make the standby active:
>SWACT (cr)
The old standby is now the active processor.
WARNING
This should not be done at a high traffic period, it may cause a loss of
AMA.
123
Verify replacement PCA has corrected original error.
124
When all maintenance activities are complete, be sure to replace the front panel of the
BMC. Carefully line up the four captive screws of the front panel with their mounting
holes. Tighten the captive screws; but do not bear down.
The procedure is complete.
297-6201-502 Standard 01.02 September 2000
(Sheet 4 of 4)