Nortel DMS-10 Series Installation, Operation And Maintenance Manual page 299

Billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

Table 4-73
CP xxx_TSK_ERR: y message
3 1 3
CP xxx_TSK_ERR: y
Display: Log message
3 1 4
Alarm Level:
N/A
3 1 5
Customer-Selected Alarm Level
3 1 6
Other Alarm Indications
3 1 7
System Recovery Action
3 1 8
Craftsperson Activity:
BMC II BISYNC Operation, Administration, and Maintenance Guide BMCB001 and up
Section 060-INDP-410 Command and Message Guide 4-139
Where:
xxx =DGN - error during a diagnostic task execution.
MMI - error during an MMI task execution.
MSG - error during a message task execution.
RPT - error during a report task execution.
y = error code
0 - internal software error
1 - unknown (error) message received from MP
2 - invoking MP failed via RFT
3 - reading data from MP failed via RFT
4 - writing data to MP failed via RFT.
Cause: a CP task encounters an internal error.
Reason Code = N/A
Corresponds to ERRMAP entry: N/A
System Default:
Type:N/ALevel:N/A
Type:Level:
Default:
Status Panel: N/AAudible:N/A
Customer-Selected
Status Panel:Audible:
None.
Refer to the 56K Interface PCA Diagnostic Procedure in
the Maintenance Procedures Guide section . If problems
continue, refer to the 56K Interface PCA Replacement
Procedure in the Maintenance Procedures Guide
section.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dms-100 series

Table of Contents