4-164 Section 060-INDP-410 Command and Message Guide
Table 7-95
DISK: BUS CONTROLLER FAILED SELF TEST message
1 2 7
DISK: BUS CONTROLLER FAILED
SELF TEST, DISK: x
Display: Log message
1 2 8
Alarm Level:
No change in disk mode
1 2 9
Customer-Selected Alarm Level
1 3 0
Other Alarm Indications
1 3 1
System Recovery Action
1 3 2
Craftsperson Activity:
297-6201-502 Standard 01.02 September 2000
Where: x = disk drive (A or B)
Cause: output when the SCSI Interface or the SCSI bus
controller fails its self test. Self test is done
automatically after any bus reset.
Reason Code = 27
Corresponds to ERRMAP entry: DISK ER MESSAGE
System Default:
Type:MinorLevel:0
Type:Level:
Default:
Status Panel:MinorAudible:Minor
Customer-Selected
Status Panel:Audible:
BMC disk system reattempts self-test. If the test fails,
the system is made non-redundant.
Refer to the Disk Drive Replacement Procedure in the
Maintenance Procedures Guide section.