REP 7.2.1 MSI Feed Roll/Retard Pad

Parts List on PL 9.2
Removal
NOTE: When replacing the MSI Feed Roll/Retard Pad, enter the Diag. mode and clear the
counter for MSI Feed.
To avoid personal injury or shock, do not perform repair or adjustment with electrical
power applied to the machine.
NOTE: The MSI Feed Roll and MSI Retard Pad must both be replaced at the same time.
1.
Remove the MSI Assembly. (REP 7.1.1)
2.
Remove the plate. (Figure 1)
1.
Remove the screws (2).
2.
Remove the plate.
Reversion 4.0
WorkCentre 7132
WARNING
3.
Remove the MSI Feed Roll. (Figure 2)
1.
Remove the ends of the roll and slide them out.
2.
Remove the ends of the roll and slide them out.
3.
Slide the MSI Feed Roll to the front and remove it.
January 2007
4-57
Figure 1 Removing the plate
Repairs/Adjustments