Piece of paper to
identify side 2
Figure 1 Identifying side 2
Adjustment
1.
Enter UI Diagnostic Mode.
Repairs/Adjustments
ADJ 15.1.4
2.
The 10 mm line is located
3.
on this scale
Chain Link Name
711-140
711-141
4.
5.
January 2007
4-268
Select NVM Read/Write.
Adjust the Lead Edge using the following NVM so that the measured value falls within
specifications.
If the measured value is short: Set a smaller value.
If the measured value is long: Set a larger value.
Table 2 NVM List
DADF Lead Reg. Adjustment (Side 1)
Replace All
DADF Lead Reg. Adjustment (Side 2)
Replace All
After adjustment is complete, perform the check following the steps in the Check proce-
dure.
Repeat the procedure until the measured value of the Lead Edge falls within the specifi-
cations.
Min.
Initial Max
Increment
80
129
230
0.458mm
80
129
230
0.458mm
Reversion 4.0