Xerox WorkCentre 7132 Service Documentation page 1157

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

REP 22.5.3 Compile Exit Sensor
Parts List on PL 22.5
Removal
To avoid personal injury or shock, do not perform repair or adjustment with electrical
power applied to the machine.
Before turning OFF the power switch, note the following to prevent loss of customer data.
[with the FAX function]
Check that the "Job in Memory" lamp is off. Press the "Job Status" button and check that no job
is in progress.
[with the Printer function]
Check that "Ready to print/send" is displayed on the Control Panel.
1.
Remove the A-Finisher from the machine.
2.
Turn over the A-Finisher.
3.
Remove the Bottom Cover. (PL 22.2)
4.
Remove the Connector Bracket. (Figure 1)
(1)Release Clamps (3) and remove the wire.
(2)Disconnect Connectors (5).
(3)Remove Screws (2).
(4)Remove Connector Bracket.
Figure 1 Removing the Connector Bracket (0fa42266)
Repairs/Adjustments
REP 22.5.3
WARNING
CAUTION
5.
Remove the Bottom Plate. (Figure 2)
(1)Release Clamps (5) and remove the wire.
(2)Disconnect Connectors (8).
(3)Release Wire from Hook.
(4)Remove Screws (4).
(5)Remove Bottom Plate.
Figure 2 Moving the Bottom Plate (j0fa42267)
6.
Remove the Compile Exit Sensor Assembly. (Figure 3)
(1)Remove Screw.
(2)Remove Compile Exit Sensor Assembly.
Figure 3 Removing the Compile Exit Sensor Assembly (j0fa42227)
January 2007
4-206
Reversion 4.0
WorkCentre 7132

Hide quick links:

Advertisement

Table of Contents
loading