102-381 UI Data Link RAP
BSD-ON:16.1
During transmission between the ESS and the UI an initialization send error or a retrieve error
for receiving data was detected by the ESS.
Initial Actions
Power Off/On
Procedure
Check the connection between the ESS and the UI.
Pull out and insert or replace the DIMM (PL 11.2).
Reload Software (ADJ 9.3.1).
Replace the ESS PWB (PL 11.2) If the problem persists, replace the Control Panel UI PWB
(PL 13.2).
Status-indicator-raps
102-381, 102-382
102-382 Application Layer Command RAP
BSD-ON:16.1
The required parameters were not sent by the UI.
A length error was detected in the variable length parameter.
A confirmation message was not received within the specified time when a request mes-
sage was sent to the UI.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 11.2).
Reload Software (ADJ 9.3.1).
Replace the ESS PWB (PL 11.2).
January 2007
2-740