Xerox WorkCentre 7132 Service Documentation page 858

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

123-387 Service Object RAP
There is an invalid service object attribute failure.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2).
Revision
WorkCentre 7132
123-388 Attribute RAP
The UI software failed attribute control.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2).
January 2007
2-825
Status-indicator-raps
123-387, 123-388