Figure 1 Disconnecting the connectors
3.
Remove the bracket. (Figure 2)
1.
Remove the screw.
2.
Loosen the screws (x2).
3.
Remove the bracket.
Repairs/Adjustments
REP 16.8.1
4.
Move the PWB Bracket in the direction of the arrow. (Figure 3)
1.
Loosen the screw.
2.
Remove the screws (x2).
3.
Remove the PWB Bracket with the connector still connected.
January 2007
4-172
Figure 2 Removing the bracket
Reversion 4.0
WorkCentre 7132