Chain-Link Name
752-060
Fail Environment SNR Humidity
752-061
Fail Environment SNR TEMP
752-091
Judge Number of ADC Fails Mcstop[N]
752-092
Judge Number of ADC Fails Mcstop[PN]
752-093
Judge Number of ADC Fails Display
752-094
Fail ADC
752-095
Fail ADC Sensor
752-096
Fail ADC ShutterOpen
752-097
Fail ADC ShutterClose
752-098
Fail ADC TCpatch[Y]
752-099
Fail ADC TCpatch[M]
752-100
Fail ADC TCpatch[C]
752-101
Fail ADC TCpatch[K]
752-102
Fail ADC patch[Y]
752-103
Fail ADC patch[M]
752-104
Fail ADC patch[C]
752-105
Fail ADC patch[K]
752-106
Fail ADC LongSetup[Y]
752-107
Fail ADC LongSetup[M]
752-108
Fail ADC LongSetup[C]
752-109
Fail ADC LongSetup[K]
752-111
Flag ADC Dirt
752-112
Vcln
752-113
Vdatk
752-114
DiffusionVcln
752-115
Vref
752-116
Vclose
752-121
Number of Continuous ADC Fails
752-127
VTCpatch[Y]
752-128
VTCpatch[M]
752-129
VTCpatch[C]
752-130
VTCpatch[K]
752-132
Vpatch[Y][B]
752-135
Vpatch[M][B]
752-138
Vpatch[C][B]
752-141
Vpatch[K][B]
752-183
Nominal RADC Target[Y]
752-184
Nominal RADC Target[M]
752-185
Nominal RADC Target[C]
General procedures information
IOT NVM List
Table 9 Process Control
Default
Range
Description
0
0~1
Humidity Sensor fail ("Standard Humidity" fixed)
0
0~1
Temperature Sensor fail ("Standard Temp" fixed)
50
0~255
Threshold used to judge MC should be forcedly stopped in response to"the number of a series of ADC
Fails." In normal mode
8
0~255
Threshold used to judge MC should be forcedly stopped in response to"the number of a series of ADC
Fails." "Flag Status: Empty Detection">=1
3
0~255
Threshold used to judge Fail should be displayed in response to "the number of a series of ADC Fails"
0
0~1
ADC Sensor Fail. This fail occurs if a specified or larger number of ADC-related fails occur.
0
0~1
ADC Sensor Fail
0
0~1
Fail: ADC Shutter stays open
0
0~1
Fail: ADC Shutter stays closed
0
0~1
TC Patch Fail
0
0~1
TC Patch Fail
0
0~1
TC Patch Fail
0
0~1
TC Patch Fail
0
0~1
Tone Patch Fail
0
0~1
Tone Patch Fail
0
0~1
Tone Patch Fail
0
0~1
Tone Patch Fail
0
0~1
Patch Density Fail during Long Setup
0
0~1
Patch Density Fail during Long Setup
0
0~1
Patch Density Fail during Long Setup
0
0~1
Patch Density Fail during Long Setup
0
0~1
Flag indicating ADC Sensor Detection Surface is contaminated.
760
0~1023
ADC average detection value of Belt-reflected light with Spectral LED On
0
0~1023
Detection value with both Spectral and Diffuse LEDs Off when Shutter closed.
30
0~1023
ADC average detection value of Belt-reflected light with Diffuse LED On
800
0~1023
Detection value with only Diffuse LED On when Shutter closed.
0
0~1023
Detection value with only Spectral LED On when Shutter closed.
0
0~255
the number of a series of ADC Fails
0
0~1023
TC Patch Vp average value
0
0~1023
TC Patch Vp average value
0
0~1023
TC Patch Vp average value
0
0~1023
TC Patch Vp average value
0
0~1023
CinB Patch ADC average detection value
0
0~1023
CinB Patch ADC average detection value
0
0~1023
CinB Patch ADC average detection value
0
0~1023
CinB Patch ADC average detection value
432
0~1023
RADC target value set up as the center
422
0~1023
RADC target value set up as the center
417
0~1023
RADC target value set up as the center
January 2007
6-64
Reversion 4.0
WorkCentre 7132