Xerox WorkCentre 7132 Service Documentation page 1386

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Chain-Link Name
749-008
749-009
749-010
749-011
749-012
Video Asic Fail R/W NG Counter
749-020
Halftone Pattern1
749-021
Halftone Pattern2
749-022
Halftone Pattern3
749-023
Halftone Pattern4
749-024
TR0 Filter Length
749-036
Lattice Pattern dot
Chain 751-xxx 752-xxx Chain 753-xxx Procon
Chain-Link Name
751-284
DRUM MAX IMPRESSION
Chain-Link Name
752-010
Flag NewPR
752-011
Flag TonerExchange[Y]
752-012
Flag TonerExchange[M]
752-013
Flag TonerExchange[C]
752-014
Flag TonerExchange[K]
752-015
Flag NewToner[Y]
752-016
Flag NewToner[M]
752-017
Flag NewToner[C]
752-018
Flag NewToner[K]
752-019
Flag NewIBT
752-020
Flag NewIBTcleaner
752-040
Temp
752-041
Humidity
Reversion 4.0
WorkCentre 7132
Table 7 ROS
Default
Range
Description
0
0~1
Rotation direction to close ROS Shutter
0: Clockwise
1: Counter Clockwise
100
100~4096
Number of input pulse per ROS Shutter open process (pps)
0
0~65535
Time period of ROS Shutter open process (10msec)
0
0~1
Rotation direction to open ROS Shutter
0: Clockwise
1: Counter Clockwise
0
0~6
the number of R/W NG results when Video ASIC Fail occurs
0
0~65535
Halftone Pattern 1
[16-bit data]
0
0~65535
Halftone Pattern 2
[16-bit data]
0
0~65535
Halftone Pattern 3
[16-bit data]
0
0~65535
Halftone Pattern 4
[16-bit data]
0
0~255
TR0 Filter Constant
[VCLK]
2
1~2
the number of dots per line in lattice pattern
Table 8 Xero/Clean
Default
Range
Description
78
0~255
Max. number of prints [1000pv]: Drum is available until a max number of prints are made.
Table 9 Process Control
Default
Range
Description
0
0~1
0: old 1: new
0
0~1
0: no replacement 1: replace
0
0~1
0: no replacement 2: replace
0
0~1
0: no replacement 3: replace
0
0~1
0: no replacement 4: replace
0
0~1
0: old 1: new
0
0~1
0: old 2: new
0
0~1
0: old 3: new
0
0~1
0: old 4: new
0
0~1
0: old 1: new
0
0~1
0: old 1: new
0
-100~100
Temperature after AD conversion (NVM100: 0 degree C)
0
0~100
Humidity after AD conversion (NVM0: 0%)
January 2007
6-63
General procedures information
IOT NVM List

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents