Xerox WorkCentre 7132 Service Documentation page 1335

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Chain-Link Name
740-084
FPGA Video Version
740-085
FPGA I/O Version
Chain 741-xxx Drive/MQ/NOHAD
Chain-Link Name
741-001
DRUM/IBT MOTOR HIGH PULSE
741-002
DRUM/IBT MOTOR LOW PULSE
741-003
DRUM/IBT MOTOR REVERSE TIME
741-004
MAIN MOTOR HIGH PULSE
741-005
MAIN MOTOR LOW PULSE
741-006
DEVE MOTOR PULSE
741-007
AUGER MOTOR PULSE
741-008
FUSER FAN DELAY TIME
741-009
REAR FAN DELAY TIME
741-011
DEW MODE TEMPERATURE OF POWERON
741-012
DEW MODE TIME FOR POWERON
741-013
FUSER FAN FAIL BYPASS
741-014
REAR FAN FAIL BYPASS
741-015
DEODORANT FILTER SW
741-016
DEW MODE TEMPERATURE OF PRINT
741-017
DEW MODE TIME FOR PRINT
741-018
DRUM MOTOR DELAY TIME
General procedures information
IOT NVM List
Table 1 Chain 740-xxx IOT Manager
Default
Range
Read/Write Description
0
0~65535
R
Version of FPGA Video Module
0
0~65535
R
Version of FPGA I/O Module
Table 2 Drive/MQ/NOHAD
Default
Range
Description
20
0~40
Fine Adjustment of Drum/IBT Motor speed (standard)
[Table No.]
20
0~40
Fine Adjustment of Drum/IBT Motor speed (half speed)
[Table No.]
20
0~40
Drum/IBT Motor Reverse Rotation Time
[50msec]
9722
8736~1073
Fine Adjustment of Main Motor speed (standard)
6
[division ratio]
19476
17474~214
Fine Adjustment of Main Motor speed (half speed)
74
[division ratio]
20
0~40
Fine Adjustment of DEVE Motor speed
[Table No.]
20
0~40
Fine Adjustment of Auger Motor speed
[Table No.]
1
0~120
Fuser Fan's delay in turning Off.
[15sec]
1
0~120
Rear Fan's delay in turning Off.
[15sec]
12
0~30
Dew Mode Threshold Temperature
[degree C]
90
1~120
Dew Mode Time
[min]
0
0~1
FUSER FAN FAIL Prevention
0: Normal Mode
1: FAN FAIL Prevention
0
0~1
REAR FAN FAIL Prevention
0: Normal Mode
1: FAN FAIL Prevention
0
0~1
Sets whether or not Deodorant Filter is present.
0: No Deodorant Filter
1: Deodorant Filter present
14
0~30
Dew Mode Threshold Temperature at the start of print
[degree C]
60
15~180
How long Fan maintains its low-speed rotation in Dew Mode at the start of print
[sec]
130
1~255
DRUM MOTOR's delay in turning OFF corresponding to FPOT
[10msec]
January 2007
6-12
Reversion 4.0
WorkCentre 7132

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents