Chain-Link Name
742-245
Timing of Temporarily Stopping Duplex Transporting
Operation
(color/L<=216mm)
742-246
Timing of Starting Duplex Feed Operation
(Exit1/color/L<=216mm)
742-247
Duplex Regi Loop Adjustment Timing (plain paper)
742-248
Duplex Regi Loop Adjustment Timing (heavy 1)
742-249
Timing of Starting Duplex Post-Regi Pushing (plain paper) 0
742-250
Timing of Starting Duplex Post-Regi Pushing (heavy 1)
742-251
Timing of Starting Duplex Post-Regi Pushing (L<=216)
742-252
Timing of Starting Duplex Post-Regi Pushing (L>216)
742-261
OCT Operation Limit
742-262
Timing of Starting OCT Initializing Operation
742-263
Timing of Starting Offset Operation (full speed/L<=216)
742-264
Timing of Starting Offset Operation (full speed/L>216)
742-265
Timing of Starting Offset Operation (half speed/L<=216)
742-266
Timing of Starting Offset Operation (half speed/L>216)
742-267
Timing of Starting Return Operation (full speed/L<=216)
742-268
Timing of Starting Return Operation (full speed/L>216)
742-269
Timing of Starting Return Operation (half speed/L<=216)
742-270
Timing of Starting Return Operation (half speed/L>216)
742-271
Limit on Countermeasure against Condensation
742-272
Timing of Starting Countermeasure Operation against
Condensation
General procedures information
IOT NVM List
Table 3 Paper Handling
Step
Read/
Default
Range
(mm)
Write
87
0~174
1.5ms
RW
67
0~134
1.5ms
RW
43
0~110
1.5ms
RW
43
0~110
1.5ms
RW
0~134
1.5ms
RW
0
0~134
1.5ms
RW
20
0~40
10.5ms RW
20
0~40
10.5ms RW
0
0~1
RW
30
0~60
10ms
RW
23
0~30
10ms
RW
0
0~30
10ms
RW
30
0~40
20ms
RW
0
0~30
20ms
RW
15
0~60
10ms
RW
15
0~60
10ms
RW
17
0~60
20ms
RW
17
0~60
20ms
RW
0
0~1
RW
1
1~250
1ñá
RW
January 2007
6-24
Description
Timing of turning Off Duplex Motor to stop paper at the Wait Station
(Duplex Wait Sensor ON to Duplex Motor OFF)
Timing of turning On Duplex Motor to restart feeding paper
Loop Amount Adjustment (Dup/plain paper)
Time from Regi Snr On to Dup Motor Off
Loop Amount Adjustment (Dup/heavy 1)
Time from Regi Snr On to Dup Motor Off
Adjusts the timing of activating Duplex Motor for Regi projection.
(Dup/plain paper/common)
Adjusts the timing of activating Duplex Motor for Regi projection
(Dup/heavy 1, coated 1/B)
Adjusts the timing of stopping Duplex Motor after Regi projection (small size)
Adjusts the timing of stopping Duplex Motor after Regi projection (large size)
BAM
0: Operation permitted
1: Operation prohibited
Adjusts the timing of starting to initialize OCT.
(From Regi Start to #2Offset Motor Homing On)
Adjusts the timing of starting Offset Operation. (full speed/L<=216)
(From Exit2 Snr Off to Offset Motor On)
Adjusts the timing of starting Offset Operation. (full speed/L>216)
(From Exit Snr2 Off to Offset Motor On)
Adjusts the timing of starting Offset Operation. (half speed/L<=216)
(From Exit2 Snr Off to Offset Motor On)
Adjusts the timing of starting Offset Operation. (half speed/L>216)
(From Exit Snr2 Off to Offset Motor On)
Adjusts the timing of starting Return-to-Offset Operation. (full speed/L<=216)
(From Exit2 Snr Off to Offset Motor On)
Adjusts the timing of starting Return-to-Offset Operation. (full speed/L>216)
(From Exit Snr2 Off to Offset Motor On)
Adjusts the timing of starting Return-to-Offset Operation. (half speed/L<=216)
(From Exit2 Snr Off to Offset Motor On)
Adjusts the timing of starting Return-to-Offset Operation. (half speed/L>216)
(From Exit Snr2 Off to Offset Motor On)
Sets whether or not to rotate #2 Exit Drive Motor in outputting paper from #1Exit
in Simplex mode.
0: enabled
1: disabled
Timing of starting to rotate #2 Exit Drive Motor; Adjusts the number of a series
of sheets for which the countermeasure against condensation is intended, in
order to start the control.