Xerox WorkCentre 7132 Service Documentation page 1202

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

6.
Scroll through the Procon "ON" Print items list, find and check that the Items in table 1
are all OK.
PRO CON On Print
Target ADC - H
ADC Measurement - H
ADC LS 1 Measurement - H
ADC LS 2 Measurement - H
Target ADC - M
ADC Measurement - M
ADC LS 1 Measurement - M
ADC LS 2 Measurement - M
Target ADC - L
ADC Measurement - L
ADC LS 1 Measurement - L
ADC LS 2 Measurement - L
ADC Patch Fail
ADC Sensor Fail
ADC Shutter open Fail
ADC Shutter close Fail
ADC Mini setup Fail
Charge Bias Voltage setting Common
Illumination Settings
Maximum Illuminations
Bias Settings
Target TC
TC Measurement
TC Patch Fail
Temperature
Humidity
Temperature Fail
Humidity Fail
Reversion 4.0
WorkCentre 7132
Table 1 PRO CON "On Print"
Yellow
Magenta
Cyan
385
340
400
368
364
395
455
402
484
352
254
307
680
605
645
656
642
663
710
675
718
635
521
586
915
910
915
923
931
937
041
951
965
831
839
835
OK
OK
OK
OK
-
-
OK
-
-
OK
OK
OK
715
715
715
396
327
321
673
673
673
575
580
580
433
423
417
400
332
341
OK
OK
OK
26
-
-
52
-
-
OK
-
-
OK
-
-
January 2007
4-251
7.
If any items indicate NG (Fail), check for failed components: Return to Call Flow and
determine component failure, etc. High Voltage Power Supply, ADC Assembly, Developer
Housing, MCU PWB, Photoreceptor, bad Developer Bias.
NOTE: Most values in this table are for reference only. Actual values will vary.
Black (K)
165
Compare the Target ADC - H with the ADC Measurement - H. The
Measurement should be within 30 bits of the Target. (Ignore ADC LS
166
1 Measurement - H and the ADC LS 2 Measurement -H)
213
If not See Corrective Action 1
127
475
Compare the Target ADC - M with the ADC Measurement - M. The
Measurement should be within 30 bits of the Target. (Ignore ADC LS
500
1 Measurement - M and the ADC LS 2 Measurement -M)
543
If not See Corrective Action 1
465
845
Compare the Target ADC - L with the ADC Measurement - L. The
Measurement should be within 30 bits of the Target. (Ignore ADC LS
848
1 Measurement - L and the ADC LS 2 Measurement -L)
866
If not See Corrective Action 1
705
OK
If NG see Corrective Action 8
-
If NG see Corrective Action 3
-
If NG see Corrective Action 2
OK
If NG see Corrective Action 9
715
If NG see Corrective Action 10
409
673
565
281
Compare the TC Target with the TC Measurement value. The Mea-
surement should be within 30 bits of the Target.
266
If not see Corrective Action 4
OK
If NG see Corrective Action 5
-
-
-
If NG see Corrective Action 6
-
If NG see Corrective Action 7
Remarks
Repairs/Adjustments
ADJ 9.1.10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents