Rep 9.2.1 Ess Pwb - Xerox WorkCentre 7132 Service Documentation

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

REP 9.2.1 ESS PWB

Parts List on PL 11.2
Removal
To avoid personal injury or shock, do not perform repair or adjustment with electrical
power applied to the machine.
Static electricity may damage electrical parts.
Always wear a wrist strap to protect electrical parts from static damage. If a wrist strap is not
available, touch some metallic parts before servicing to discharge the static electricity.
Perform GP 4 Part 2 after each PWB is replaced. To maintain the integrity of the serial number
and billing data NEVER replace all of the PWBs at once. Replacing all three PWBs at once will
cause unrecoverable NVM corruption. If a PWB needs replacing, only replace ONE AT A TIME
and perform this procedure after each one is replaced. If the problem is not resolved, reinstall
the original PWB and re-enter the serial number (if necessary) before attempting to replace a
different PWB.
1.
Go to GP 4 Replacing Billing PWBs and perform PART 1 to document Customer Settings
and Machine Settings.
2.
Switch off the power and disconnect the power cord.
3.
Remove the ESS Cover, the MCU Cover and the Rear Lower Cover. (REP 10.2.1)
4.
Disconnect all the connectors (5) on the ESS PWB. (Figure 1)
Disconnect the con-
nectors (3) and remove
harness from wire
clamps.
Disconnect the connec-
tors (2)
Figure 1 Disconnecting the connectors on the ESS PWB
Repairs/Adjustments
REP 9.2.1
WARNING
CAUTION
CAUTION
5.
Disconnect the connectors from the MCU PWB. (Figure 2, Figure 3)
Figure 2 Disconnecting 13 of the connectors on the MCU PWB
May 2006
4-62
Disconnect the connec-
tors and remove the har-
ness from the wire clamps
Disconnect the Connec-
tors and remove the har-
ness from the wire clamps