116-364 Timer RAP
A timer failure is detected in the ESS PWB.
Initial Actions
Power Off/On
Procedure
Check the connection of each ESS PWB connector. The connectors are correctly con-
nected.
Y
N
Connect the connectors.
Turn on the power again. The problem persists.
Y
N
Return to Service Call Procedures.
Replace the ESS PWB (PL 11.2).
Revision
WorkCentre 7132
116-365 Spool RAP
An internal shutdown occurred after an SPL processing error.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 11.2).
If the problem persists perform Hard Disk Diagnostic Program.
If the problem persists replace the HDD (PL 11.2).
January 2007
2-765
Status-indicator-raps
116-364, 116-365