Xerox WorkCentre 7132 Service Documentation page 860

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

123-391 Job Parameter RAP
The UI software failed job parameter control.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2).
Revision
WorkCentre 7132
123-392 Auditron RAP
The UI software failed auditron control.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2).
January 2007
2-827
Status-indicator-raps
123-391, 123-392