Xerox WorkCentre 7132 Service Documentation page 1351

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Chain-Link Name
744-199
Fine Adjustment of Fuser Mot Speed: heavy 2
744-200
Fuser Mot Off Time
744-201
Fuser Mot Off Time half speed
744-266
Fine Adjustment of Fuser Mot Speed
coated paper 1 B/W
744-267
Fine Adjustment of Fuser Mot Speed
coated paper 1 F/C
Chain 746-xxx Chain 747-xxx Xfer
Chain-Link Name
746-001
Environment control execution switch
746-002
Compulsory designated environment NO
746-003
The relative temperature threshold value to specify environment NO. #0
746-004
absolute humidity AH threshold value to specify environment NO. #0
746-005
Storage of calculated value of absolute humidity
746-006
Storage of selected Environment No.
746-007
1st BTR On Timing
746-008
1st BTR Output changeover Timing (Y->M->C)
746-009
1st BTR Output changeover Timing (full->half)
746-010
1st BTR Off Timing (full)
746-011
1st BTR Off Timing (half)
746-012
The amount of a film compensation electric current
746-013
A film decreases, compensation electric current calculation result storage
746-014
1st BTR Mode environment revise (BW_Side1)
746-015
1st BTR Mode environment revise (BW_Side2)
746-016
1st BTR Mode environment revise (FC_Side1)
746-017
1st BTR Mode environment revise (FC_Side2)
746-018
1st BTR Halfspeed time output compensation coefficient
746-020
1st BTR Environment compensation coefficient NotUsually
(environment NO.1-3_K)
746-021
1st BTR Environment compensation coefficient NotUsually
(environment NO.4-6_K)
746-022
1st BTR Environment compensation coefficient NotUsually
(environment NO.7_K)
746-023
1st BTR Environment compensation coefficient NotUsually
(environment NO.8-9_K)
746-024
1st BTR Environment compensation coefficient NotUsually
(environment NO.0_YMC)
General procedures information
IOT NVM List
Table 4 Fuser
Read/
Default
Range
Step
Write
20376
19540~22344
RW
200
0~255
10msec RW
82
0~255
10msec RW
10235
9770~11172
RW
20440
19540~22344
RW
Table 5 Xfer
Default
Range
1
0~1
5
0~9
22
0~100
3
0~20
10
0~255
5
0~9
60
0~200
45
0~200
0
0~50
56
0~200
464
300~550
2
0~20
0
0~255
100
0~200
100
0~200
100
0~200
100
0~200
50
0~200
100
0~200
100
0~200
100
0~200
100
0~200
100
0~200
January 2007
6-28
Description
79mm/s (-0.2%)
Detects Exit SNR OFF.
Detects Exit SNR OFF.
158mm/s(-0.7%)
79mm/s(-0.5%)
Description
Environment control execution switch
Compulsory designated environment NO
The relative temperature threshold value to specify environment NO. #0
absolute humidity AH threshold value to specify environment NO. #0
Stores a calculated value of absolute humidity.
Stores a selected Environment No.
1st BTR On Timing
1st BTR Output changeover Timing (Y->M->C)
1st BTR Output changeover Timing (full->half)
1st BTR Off Timing (full Speed)
1st BTR Off Timing (halfSpeed)
The amount of a film compensation electric current
A film decreases, compensation electric current calculation result storage
1st BTR Mode environment revise (BW_Side1)
1st BTR Mode environment revise (BW_Side2)
1st BTR Mode environment revise (FC_Side1)
1st BTR Mode environment revise (FC_Side2)
1st BTR Halfspeed time output compensation coefficient
1st BTR Environment compensation coefficient NotUsually
(environment NO.1-3_K)
1st BTR Environment compensation coefficient NotUsually
(environment NO.4-6_K)
1st BTR Environment compensation coefficient NotUsually
(environment NO.7_K)
1st BTR Environment compensation coefficient NotUsually
(environment NO.8-9_K)
1st BTR Environment compensation coefficient NotUsually
(environment NO.0_YMC)
Reversion 4.0
WorkCentre 7132