REP 4.3.1 Sensor Bar

Parts List on PL 11.1
Removal
1.
Switch off the power and disconnect the Power Cord.
2.
Remove the IBT Module. (REP 4.2.2)
3.
Prepare to remove the Sensor Bar.
a.
Release the harness clamps (2).
b.
Disconnect the connectors (2).
c.
Remove the screw (1).
Figure 1 Preparing to remove the Sensor Bar
4.
Remove the Sensor Bar (PL 11.1).
Repairs/Adjustments